List 4 Telecom Central Office Power Cable

RG Flex telecommunications power products, also known as DC power cables or central office power cables, have been tested and certified by Telcordia and meet the functional performance requirements of GR-347 Issue 3, TPR.9212 and ATIS-0600017.2020. Telcordia affirms that L2, L3 and L4 power cables are suitable for use in all telecommunications applications including central offices, remote terminal applications and outside plant remote cabinets that house electronics equipment.

Jupiter Communications knows that in order for the telecom infrastructure to remain sound, engineers and procurement specialists must source high quality materials that meet all the necessary industry specifications and also ensure a specifications entire list of components is available for technicians.  In addition to Jupiter Communications’ Telcordia-certified RG Flex line, Jupiter is also proud to offer the industry’s leading lugs from Burndy. From cables to lugs to all other connectivity solutions, Jupiter Communications can ensure your power solutions are comprised of the best components.

Available Cable Constructions

To see availability and pricing, please visit our sister site IEWC.com here>

Size AWG or kcmil Stranding Number/dia (inch) Conductor diameter (inches) Insulation min. Thickness (mils) Nominal insulation diameter (inches) Nominal braid diameter (inches) Max.d.c.res. @ 20°C (ohms/mft.) Approx. Weight lbs./mft.
8 41/0.0201 0.147 60 0.28 0.342 0.68 98.1
6 65/0.0201 0.192 60 0.315 0.381 0.436 135.3
4 105/0.0201 0.257 60 0.39 0.452 0.274 195.5
2 165/0.0201 0.309 60 0.441 0.508 0.172 278.5
1 210/0.0201 0.346 80 0.512 0.59 0.137 361
1/0 266/0.0201 0.398 80 0.571 0.641 0.109 442.8
2/0 342/0.0201 0.455 80 0.626 0.7 0.087 548.1
4/0 532/0.0201 0.571 80 0.736 0.814 0.055 804.1
350 882/0.0201 0.752 95 0.953 1.027 0.034 1254.9
500 1221/0.0201 0.894 95 1.087 1.157 0.023 1676
750 1850/0.0201 1.067 110 1.307 1.382 0.016 2499.6

Technical Specifications

View spec sheet as PDF

Operating Voltage
600V
Max Operating Temp
105 °C dry & 75°C wet
Flame Test
VW-1 and FT4
Low Smoke Test
ST1
Halogen Free
IEC60754 IEC60332
Conductor
Type L4 DC Power Cable has a Class I annealed tinned copper flexible stranded conductor as per ASTM-B-33 and B172. A mylar tape is applied over the conductor to facilitate easy stripping.
Insulation
Thermosetting low-smoke, lead-free and silicone-free non-halogenated insulation, rated 90°C.
Protective Layer
Woven cotton braid, saturated with heat resistant, moisture resistant, and flame retardant compound.
Packaging
The ends of all cables supplied shall be capped or taped to prevent the ingress of moisture during shipping or storage.
Testing
Physical and electrical testing in accordance with the requirements of UL   Standard 44, Subject 509 and 758, and CSA Standard C22.2 No. 210.2 M90 as AWM.
Cable Sheath Markings
RHH/RHW Marking: RG FLEX L4 NON-HAL (UL) E477980 __ AWG RHH/RHW 90C DRY AND 75C WET FT4-ST1 3578 105C 600V VW-1 - c(UL) AWM I B 105C 600V FT4 ---- MEETS IEC60754, IEC60332 xxx FT
Sequential footage markings shall be applied at two foot intervals on one side of the cable. Add "FOR CT USE" before "(AWM 3578)" on sizes 1/0 AWG and larger.

Reference

Tested and certified to meet or exceed the following standards:

  • Telcordia GR-347-CORE Compliant
  • ATIS 0600017.2020 Compliant
  • TPR.9212 Compliant
  • UL 2731 Telecommunications Central Office Power Cable
  • UL Listed Standard 44: Thermoset Insulated Type RHH/RHW/ST1
  • UL Listed: For Tray Cable Use (1/0 & Larger)
  • FT-4 Flame Test Compliant
  • VW-1 Flame Test Compliant
  • CSA AWM 1 B 105C
  • Zero Halogen
  • IEC 60754 and IEC 60332 Compliant
  • RoHS / Reach Compliant

Jupiter Communications is the exclusive distributor for all RG Flex power cables in North America.

Please call us today for price and availability.