List 4 Telecom Central Office Power Cable
RG Flex telecommunications power products, also known as DC power cables or central office power cables, have been tested and certified by Telcordia and meet the functional performance requirements of GR-347 Issue 3, TPR.9212 and ATIS-0600017.2014. Telcordia affirms that L2, L3 and L4 power cables are suitable for use in all telecommunications applications including central offices, remote terminal applications and outside plant remote cabinets that house electronics equipment.
Jupiter Communications knows that in order for the telecom infrastructure to remain sound, engineers and procurement specialists must source high quality materials that meet all the necessary industry specifications and also ensure a specifications entire list of components is available for technicians. In addition to Jupiter Communications’ Telcordia-certified RG Flex line, Jupiter is also proud to offer the industry’s leading lugs from Burndy. From cables to lugs to all other connectivity solutions, Jupiter Communications can ensure your power solutions are comprised of the best components.
Available Cable Constructions
Size AWG or kcmil | Stranding Number/dia (inch) | Conductor diameter (inches) | Insulation min. Thickness (mils) | Nominal insulation diameter (inches) | Nominal braid diameter (inches) | Max.d.c.res. @ 20°C (ohms/mft.) | Approx. Weight lbs./mft. |
---|---|---|---|---|---|---|---|
8 | 41/0.0201 | 0.147 | 60 | 0.28 | 0.342 | 0.68 | 98.1 |
6 | 65/0.0201 | 0.192 | 60 | 0.315 | 0.381 | 0.436 | 135.3 |
4 | 105/0.0201 | 0.257 | 60 | 0.39 | 0.452 | 0.274 | 195.5 |
2 | 165/0.0201 | 0.309 | 60 | 0.441 | 0.508 | 0.172 | 278.5 |
1 | 210/0.0201 | 0.346 | 80 | 0.512 | 0.59 | 0.137 | 361 |
1/0 | 266/0.0201 | 0.398 | 80 | 0.571 | 0.641 | 0.109 | 442.8 |
2/0 | 342/0.0201 | 0.455 | 80 | 0.626 | 0.7 | 0.087 | 548.1 |
4/0 | 532/0.0201 | 0.571 | 80 | 0.736 | 0.814 | 0.055 | 804.1 |
350 | 882/0.0201 | 0.752 | 95 | 0.953 | 1.027 | 0.034 | 1254.9 |
500 | 1221/0.0201 | 0.894 | 95 | 1.087 | 1.157 | 0.023 | 1676 |
750 | 1850/0.0201 | 1.067 | 110 | 1.307 | 1.382 | 0.016 | 2499.6 |
Technical Specifications
Operating Voltage |
600V | |
Max Operating Temp |
105 °C dry & 75°C wet | |
Flame Test |
VW-1 and FT4 | |
Low Smoke Test |
ST1 | |
Halogen Free |
IEC60754 IEC60332 | |
Conductor |
Type L4 DC Power Cable has a Class I annealed tinned copper flexible stranded conductor as per ASTM-B-33 and B172. A mylar tape is applied over the conductor to facilitate easy stripping. | |
Insulation |
Thermosetting low-smoke, lead-free and silicone-free non-halogenated insulation, rated 90°C. | |
Protective Layer |
Woven cotton braid, saturated with heat resistant, moisture resistant, and flame retardant compound. | |
Packaging |
The ends of all cables supplied shall be capped or taped to prevent the ingress of moisture during shipping or storage. | |
Testing |
Physical and electrical testing in accordance with the requirements of UL Standard 44, Subject 509 and 758, and CSA Standard C22.2 No. 210.2 M90 as AWM. | |
Cable Sheath Markings |
RHH/RHW Marking: RG FLEX L4 NON-HAL (UL) E477980 __ AWG RHH/RHW 90C DRY AND 75C WET FT4-ST1 3578 105C 600V VW-1 - c(UL) AWM I B 105C 600V FT4 ---- MEETS IEC60754, IEC60332 xxx FT Sequential footage markings shall be applied at two foot intervals on one side of the cable. Add "FOR CT USE" before "(AWM 3578)" on sizes 1/0 AWG and larger. |
Reference
Tested and certified to meet or exceed the following standards:
- Telcordia GR-347-CORE Compliant
- ATIS 0600017.2014 Compliant
- TPR.9212 Compliant
- UL 2731 Telecommunications Central Office Power Cable
- UL Listed Standard 44: Thermoset Insulated Type RHH/RHW/ST1
- UL Listed: For Tray Cable Use (1/0 & Larger)
- FT-4 Flame Test Compliant
- VW-1 Flame Test Compliant
- CSA AWM 1 B 105C
- Zero Halogen
- IEC 60754 and IEC 60332 Compliant
- RoHS / Reach Compliant

Jupiter Communications is the exclusive distributor for all RG Flex power cables in North America.
Please call us today for price and availability.